| Customization: | Available |
|---|---|
| Technology: | Infrared |
| Style: | Box Camera |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Model | KTVC4101-1920 | KTVC4102-1920 | KTVC4105-1920 |
| FOV | 43.6°*32.7° | 27°*20.2° | 11°*8.2° |
| Thermal sensor | 5th generation UFPA | ||
| Resolution | 384*288 pixel(640*512 optional) | ||
| Spectral response | 7.5~14μm | ||
| NETD | 50mK(@25ºC F1.0) | ||
| Thermal lens | 10mm F1.0 | 20mm F1.0 | 50mm F1.0 |
| Visible CCD | 1/2.8'' CMOS, 2 mega pixels, ICR optical filter, auto color to B/W. | ||
| Visible lens | 4.7~94mm lens,motorized zoom and focus. | ||
| Image processing | 1. Stable operation temperature without TEC, starting time less than 4 seconds | ||
| 2. SDE digital image processing | |||
| 3. 10 pseudo color and B/W, B/W conversion | |||
| 4. 2X digital amplification | |||
| Temperature accuracy | 1. Temperature accuracy: ±2ºC or ±2% of reading,take the maximum | ||
| 2. Temperature range: -20ºC-120ºC(650ºC optional) | |||
| 3. Adjustable parameters, include temperature correction, emissivity, atomospheric transimissivity, humidity | |||
| Temperature model | 1. Support high, low and average temperature tracking, point, line and rectangular detection; multi addable detection targets | ||
| 2. Each road can be set up to 10 alarm region, independent threshold value and sampling cycle setting, independent curve chart | |||
| 3. Fixed point monitoring, multi areas addable. | |||
| Overheat alarm | 1. 6 kinds of alarm algorithm, maximum, minimum, average, middle position absolute threshold and airspace relative, time domain, relative value alarm temperature mutations | ||
| 2. Sound, light alarm. Presets a linkage visible light camera ptz automatic observation target. Reserved switch alarm output, manual/automatic fire extinguishing system and the broadcasting system | |||
| Alarm log | 1. Real-time record each object temperature data, automatically generate trend curve. | ||
| 2. Can automatic storage temperature when trigger the alarm data, snapshot images and videos, establish and record the related logs, video storage, real-time playback | |||
| PT | 1. Duty: 15kg | ||
| 2. Rotation: pan: 0~360°, tilt: -75~+40° | |||
| 3. Rotation speed: Pan: 0.1~60°/S, tilt:0.1~30°/S | |||
| 4. 256 presets | |||
| 5.Anti-shake | |||
| Interface | 1. One RJ45 network interface (including video and temperature data, azimuth of return data, PT control transmission), one switch alarm output (linkage acousto-optic alarm, start, fire control system) | ||
| 2. AC24V/DC24V | |||
| 3. Waterproof aviation connector | |||
| Environment parameters | 1. 1. Protection:One integral aluminum alloy housing, IP66 | ||
| 2. Operational temp.: -25°~55°(-45°optional) | |||
| 3. Power consumption: common 50W, peak 100W | |||
| Model | KTC4101 | KTC4102 | KTC4101-EP | KTC4102-EP |
| FOV | 43.6°*32.7° | 27°*20.2° | 43.6°*32.7° | 27°*20.2° |
| Thermal sensor | 5th generation UFPA | |||
| Resolution | 384*288 pixel(640*512 optional) | |||
| Spectral response | 7.5~14μm | |||
| NETD | 50mK(@25ºC F1.0) | |||
| Thermal lens | 10mm F1.0 | 20mm F1.0 | 10mm F1.0 | 20mm F1.0 |
| Housing | 1, One integral aluminum alloy housing | 1,Explosion-proof housing, 304 stainless steel, One integral aluminum alloy housing, no connecting line outside | ||
| 2, IP66 ingress protection | 2,ExdCT6 / DIP A20 TA,T6 certified, ALO | |||
| 3,IP68 | ||||
| Image processing | 1. Stable operation temperature without TEC, starting time less than 4 seconds | |||
| 2. SDE digital image processing | ||||
| 3. 10 pseudo color and B/W, B/W conversion | ||||
| 4. 2X digital amplification | ||||
| Temperature accuracy | 1. Temperature accuracy: ±2ºC or ±2% of reading, take the maximum | |||
| 2. Temperature range: -20ºC-120ºC(650ºC optional) | ||||
| 3. Adjustable parameters, include temperature correction, emissivity, atomospheric transimissivity, humidity | ||||
| Temperature model | 1. Support high, low and average temperature tracking, point, line and rectangular detection; multi addable detection targets | |||
| 2. Each road can be set up to 10 alarm region, independent threshold value and sampling cycle setting, independent curve chart | ||||
| 3. Fixed point monitoring, multi areas addable. | ||||
| Overheat alarm | 1. 6 kinds of alarm algorithm, maximum, minimum, average, middle position absolute threshold and airspace relative, time domain, relative value alarm temperature mutations | |||
| 2. Sound, light alarm. Presets a linkage visible light camera ptz automatic observation target. Reserved switch alarm output, manual/automatic fire extinguishing system and the broadcasting system | ||||
| Alarm log | 1. Real-time record each object temperature data, automatically generate trend curve. | |||
| 2. Can automatic storage temperature when trigger the alarm data, snapshot images and videos, establish and record the related logs, video storage, real-time playback | ||||
| Interface | 1. One RJ45 network interface (including video and temperature data), one switch alarm output (linkage acousto-optic alarm, start, fire control system) | |||
| 2. AC24V/DC24V | ||||
| 3. Waterproof aviation connector | ||||
| Environment parameters | 1. Operational temp.: -25ºC~55ºC(-45ºC optional) | |||
| 2. Power consumption: common 10W, peak 20W | ||||